Receivers M880

Receiver M880 S

 

Small and flexible

The receiver S, thanks to its minimum size (127x70x147 mm), can be installed in small spaces.

 

TECHNICAL DATA
   

                                       

RECEIVING UNIT MODEL
M880 S AC
M880 S DC

Harting connector

(PCB415)

M880 S DC

DEUTSCH connector

(PCB410)

Supply voltage 24Vac (50-60HZ) 11÷30 Vdc 11÷30 Vdc 11÷30 Vdc
Safety control 1 safety-enable relay, 2 Stop relays 1 safety-enable relay, 2 Stop relays 1 safety-enable relay, 2 Stop relays
Max. no. of ON/OFF controls 14 relays Up to 14 MOSFET 8 MOSFET
2 STOP relays

ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) 

or

ISO 13849-1:2006 6.2.6 architecture, (PLC Cat 1)                                 

(excluding ARES2 C)                             

(excluding WAVE2 C)

ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) 

or

ISO 13849-1:2006 6.2.6 architecture, (PLC Cat 1)           

(excluding ARES2 C)                    

(excluding WAVE2 C)

ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) 

or

ISO 13849-1:2006 6.2.6 architecture, (PLC Cat 1)      

(excluding ARES2 C)                  

(excluding WAVE2 C)

Max. no. of analog controls N.D. 4 N.D.
Service commands Start, Horn Start, Horn Start, Horn, 
Serial ports N.D. CAN, RS232, RS485 CAN, RS232, RS485
Analog commands N.D. 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, 
0 ÷ ±10Vdc
PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc
N.D.
Operating temperature -25°C ÷ +70°C -25°C ÷ +70°C -25°C ÷ +70°C
Storage temperature -40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +85°C
Size (L x P x A) 127 x 70 x 147 mm 127 x 70 x 147 mm 127 x 70 x 147 mm
Weight 630 g 630 g 630 g
Serial cable between TX and RX YES * YES YES *
Integrated blinklight YES NO NO
External antenna YES ** YES ** NO
Protection class IP 66 IP 66 IP 66

 

* If DEUTSCH no serial cable

** If Harting or DEUTSCH no external antenna 

 

 

 

Receiver M880 L​

 

Thanks to its compact size and extreme versatility, the M880 L receiver is perfect for a wide range of on/off applications in AC and DC, as well as for standard proportional applications in DC, such as hydraulic cranes.
It may be installed on the machine in an easy and non-invasive way. 
 
TECHNICAL DATA
RECEIVING UNIT MODEL
M880 L AC
M880 L DC
Supply voltage 24÷240Vac (50-60Hz), 30VA, max 1.2A @24Vac 11÷30Vdc, max 2A @11Vdc
Safety controls Safety-enable relay, 2 Stop relays Safety-enable relay, 2 Stop relays
Max. no. of ON/OFF controls 20 relays or MOSFET 20 relays or MOSFET
Mx. no. of analog controls 8 8
Service commands Start, Horn, Timed-relay Start, Horn, Timed-relay
2 STOP relays

ISO 13849-1:2006 6.2.7 architecture
(excluding ARES2 C)                     (excluding WAVE2 C)

ISO 13849-1:2006 6.2.7 architecture (excluding ARES2 C)                   (excluding WAVE2 C)

Input port CAN, Serial CAN, Serial
Proportional commands N.A. 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, 
0 ÷ ±10Vdc
PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc
Proportional commands CAN (ID 11-29 bit)
CANOpen (ID 11-29 bit)
RS232/RS485
CAN (ID 11-29 bit)
CANOpen (ID 11-29 bit)
RS232/RS485
Operating temperature -25°C ÷ +70°C -25°C ÷ +70°C
Storage temperature -40°C ÷ +85°C -40°C ÷ +85°C
Size (L x P x A) 145 x 65 x 230 mm 145 x 65 x 230 mm
Protection class IP66 IP66

 

 
 
 

Receiver M880 H


The M880 H receiver can be paired with transmitting units that require executing a significant number and variety of commands.
 
TECHNICAL DATA
RECEIVING UNIT MODEL
M880 H AC
M880 H DC
Supply voltage 24Vac (50-60Hz), 68VA, max 2.8A
45÷240Vac (50-60Hz), 45VA, max 1,1A @45Vac
11÷30Vdc, max 4A @11Vdc, 44W
Safety control Up to 6 safety-enable relays, 2 Stop relays Up to 6 safety-enable relays, 2 Stop relays
Max. no. of ON/OFF controls 73 relays or MOSFET 73 relays or MOSFET
Max. no. of analog controls 32 32
Service commands Start, Horn, Timed-relay Start, Horn, Timed-relay
2 STOP relays

ISO 13849-1:2006 6.2.7 architecture
(excluding ARES2 C)                    (excluding WAVE 2C)

ISO 13849-1:2006 6.2.7 architecture
(excluding ARES2 C)                    (excluding WAVE 2C)
Input port CAN, Serial CAN, Serial
Proportional commands N.A. 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, 
0 ÷ ±10Vdc
PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc
Communication protocols CAN (ID 11-29 bit)
CANOpen (ID 11-29 bit)
RS232/RS485
CAN (ID 11-29 bit)
CANOpen (ID 11-29 bit)
RS232/RS485
Operating temperature -25°C ÷ +70°C -25°C ÷ +70°C
Storage temperature -40°C ÷ +85°C -40°C ÷ +85°C
Size (L x P x A) 205 x 130 x 280 mm 205 x 130 x 280 mm
Protection class IP66 IP66
 

 

 

 

Receiver M880 M AC

 

The M AC receiver has been conceived and designed to be installed inside the power cabinet of the machine, thanks to its convenient DIN-rail fitting.

 
TECHNICAL DATA
RECEIVING UNIT MODEL
M880 M AC
 
Supply voltage MAC:12-30 Vdc / 24 Vac (50-60 Hz)  
Safety controls 2 STOP, 1 Safety-Enable  
Max. no. of ON/OFF controls 24 relays (20 N.0: and 4 N.C. /N.O.)  
Max. no. of analog controls 4  
Service commands Start, Lamp, (Between 24 relays)  
2 STOP relays

ISO 13849-1:2006 6.2.7 architecture

(excluding ARES2 C)                           (excluding WAVE2 C)

 

Iput port CAN, Serial 232, 485  
Proportional commands 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, 
0 ÷ ±10Vdc
25%-50%-75% Vcc
 
Communication protocols CAN (ID 11-29 bit)
CANOpen (ID 11-29 bit)
RS232/RS485
 
Operating temperature -25°C ÷ +70°C  
Storage temperature -40°C ÷ +85°C  
Size (L x P x A) 180 x 73 x 120 mm  
Protection class IP20  

 

 

 

 

  

ATEX CERTIFIED RECEIVING UNIT


Device of group II. Device designed for environments in which explosive atmospheres may occur;

High protection level: category 2. Intended for use in enviroments in which explosive atmospheres may occur due to gases, vapours, mists or ir and dust mixtures;
Protection system for potentially explosive gases and dusts. The device remains powered and keeps operating in zones 1, 2 (G) e 21, 22 (D);
Explosion-proof housing;
Temperature class 85°C;
Fully protected against dust and powerful water jets (IP66);
Case equipped with a 1” IOS7/1RC and ¾” IOS7/1RC barrier for reinforced cables with specifications: ATEX Ex ll2GD Exd ll C IP 66;

Operating radious 70 m without obstacles.

 

 

Torna all'inizio pagina